For the complete documentation index, see llms.txt. This page is also available as Markdown.

PSE Detection

PSE Detection analyzes video for luminance flashes, red flashes, and optional spatial patterns that can trigger photosensitive epilepsy. Findings appear in the QC panel and timeline and can be exported as JSON or HTML reports.

Enable PSE Detection

  1. Open the QC panel.

  2. Enable PSE Detection.

  3. Select the required standard: ITU-R BT.1702-3, Ofcom, or NHK/JBA.

  4. Enable Pattern detection when spatial-pattern analysis is required. This option is off by default and adds an extra GPU analysis pass.

OmniScope analyzes every processed frame over a sliding time window. Motion estimation helps distinguish image motion from flashing.

Thresholds

Setting
Description
Default

Flash frequency

Flash rate used by the selected standard

3 Hz

Luminance threshold

Minimum luminance change counted as a flash

20 cd/m²

Screen coverage

Minimum affected screen area

25%

Select Reset to default thresholds to restore these three values. The selected standard, transfer function, and other PSE settings are not changed.

Changing thresholds or the display model clears the current temporal history, so frames analyzed with different settings are not combined into one result.

Ofcom Profile

The Ofcom profile follows the 2005 guidance for luminance flashes:

  • A luminance flash requires the darker state to be below 160 cd/m².

  • SDR analysis uses a 2.2 gamma and 200 cd/m² reference white.

  • The coverage rule is more than 25% of the screen.

  • Red-flash analysis remains independent of the 160 cd/m² luminance restriction.

These values are included in exported PSE reports.

Results and Reports

The QC panel shows the current risk level together with measured flash frequency, luminance difference, and screen coverage. Errors and warnings are also recorded on the QC Timeline for frame-by-frame review.

PSE reports are available in JSON and HTML. Reports include the selected standard, thresholds, event categories, frame ranges, timecodes, peak measurements, and the overall compliance result.

Last updated